Open skirting trunking - practical, versatile, flexible
FAQs on the open skirting trunking system
Which basic types are available?

45 mm system opening

80 mm system opening
Which variants are available?
Rapid 45
Material | Trunking height in mm | Trunking width in mm | RAL 9010 pure white | RAL 7035 light grey | Anodised | Special colour |
Plastic1 | 53 | 100 | Yes | Yes | ||
Plastic2 | 53 | 130 | Yes | Yes | ||
165 | Yes | Yes | ||||
Plastic3 | 53 | 160 | Yes | Yes | ||
Aluminium1 | 53 | 100 | Yes | Yes | Yes | |
Aluminium2 | 53 | 165 | Yes | Yes | Yes | |
53 | 165 | Yes | Yes | Yes |
Rapid 80
Material | Trunking height in mm | Trunking width in mm | RAL 9010 pure white | RAL 9001 cream | RAL 7035 light grey | RAL 7030 stone grey | Anodised | Special colour |
Plastic1 | 70 | 110 | Yes | Yes | Yes | Yes | ||
130 | Yes | Yes | Yes | Yes | ||||
170 | Yes | Yes | Yes | Yes | ||||
Sheet steel1 | 70/90 | 110 | Yes | |||||
130 | Yes | Yes | ||||||
170 | Yes | Yes | ||||||
210 | Yes | Yes | ||||||
Sheet steel2 | 70/90 | 170 | Yes | Yes | ||||
210 | Yes | Yes | ||||||
Aluminium1 | 70 | 110 | Yes | Yes | Yes | |||
130 | Yes | Yes | Yes | |||||
90 | 130 | Yes | Yes | Yes | ||||
70 | 170 | Yes | Yes | Yes | ||||
Aluminium2 | 90 | 210 | Yes | Yes | Yes |
1 Single-compartment
2 Two-compartment
3 Three-compartment
What additional fittings exist?

External corner, variable

External corner

T piece adapter

End piece

Internal corner, variable

Internal corner

Flat angle

Flat angle cover
How can noise transmission be reduced?
In modern office buildings, device installation trunking is often run through office partitions, creating a connection between multiple offices. Here, there is the problem that noise may be carried through the trunking penetration.
To prevent air conduction of noise, the free cross-section of the trunking remaining can filled with noise insulation after cabling, e.g. air noise barrier, type 7 LSB. The same applies to any gaps between the trunking and the adjoining wall.
When used correctly, the air noise barrier, type 7 LSB, can achieve attenuation of up to 40 dB.
Why is there halogen-free skirting trunking?
Flame-protection agents, based on halogen compounds such as fluorine, iodine, chlorine and bromine, are used to keep the flammability of PVC low. If there is a fire, this safety aspect becomes a dangerous disadvantage: toxic smoke gases, such as carbon dioxide and carbon monoxide, are created. These usually endanger people far faster than flames and heat. Therefore, from a fire protection perspective, halogen-free installation materials are a safe alternative. Completely manufactured from halogen-free plastics, if there is a fire, it reduces the amount of toxic smoke gases and the formation of corrosive substances.
Connectable device installation for Rapid 45?
Modul 45connect stands out through its innovative socket and adapter components and offers numerous application options. The connection adapter, with which sockets can be arranged easily, creates a high level of flexibility.
Thus, it is possible to create multi-socket combinations without the need for additional wiring. Combinations with a maximum of two connection adapters are tested and VDE-approved. 4x to 9x socket combinations can be created easily.